Uninterruptable Power Supply
SENTINEL 6 RACK 700 - 3000VA
Sentinel 6 Rack is a range of UPSs with ON- LINE double conversion technology and with "zero" transfer time. The load is always powered by the inverter, which supplies true sinusoidal voltage that is free from electrical interference. |
![]() |
High immunity against Electromagnetic Disturbances
The unit will have high immunity against the electromagnetic disturbances coming from intended Radio frequency emitters according to the standard IEC 61000-4-2 (Level 4) IEC 61000-4-2 (Level 3) IEC 61000-4- 4 (Level 4), IEC 1000-4-5 (Level 4). Total microprocessor control Digital control of the appliance considerably improves system reliability, reduces unit dimensions and weight, and significantly increases control and communications capabilities.
Battery optimization
The UPS periodically performs a battery efficiency test. The batteries are not activated during micro interruptions (40 ms), which are the most common type of mains interference, since the required power is drawn from the capacitors banks. This system (battery saving) extends the life of the batteries. The Sentinel 6 Rack range will also include the deep battery discharge feature to protect the battery.
Advanced communication
The EPI Watch & Save software ensures effective and intuitive management of the UPS. Important information such as the input and output voltage, the load applied, the remaining back-up time, etc., is displayed in the form of bar graphs. The software is able to provide information even in the event of a failure, and can also programme the UPS for automatic weekly start-up and shutdown.
Communication Expansion Slot
Sentinel 6 Rack comes with an expansion slot for optional communication boards which make Sentinel 6 Rack compatible with the main communication options: Netman 102, MultiCom 302, RS232 +RS485 ports, Multi Com 352.
Automatic restart
The UPS is programmed to restart automatically when the mains power supply returns after switching off due to the end of back-up time following a prolonged power failure.
Extending the back-up time
Battery expansion is envisaged to increase the back-up time of the UPS. For longer back-up times, the Sentinel 6 Rack POWER contains an even more powerful battery charger.
Reduced noise
Through the use of high frequency components and fan speed control, the noise level of the UPS is under 45 dBA.
Manual By-Pass
The By-pass provides the possibility of excluding a UPS for maintenance without any interruptions or disturbances of the load supply.
Protection of the telephone line
Sentinel 6 Rack comes with an RJ45/RJ11 Network/Telephone socket to guarantee the protection of its telephone or network line against any overvoltages.
Applications
Small/medium computer networks, Local Area Networks (LAN), Workstation, Servers, EPOS (Electronic Point of Sale) systems.
Note
2 years warranty
Technical Data


Product characteristics may be changed to meet specific customer demands.
To find out more, please call one of our consultants on +35 (0) 540 11519 or